A.R. ALATAN SAINS (K) SDN. BHD.

subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link
subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link
subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link
subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link
subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link
subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link
subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link
subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link

VISCOMETERS

 

GLASS CAPILLARY VISCOMETER (FENSKE ROUTINE)
Brand : Cannon

  • The Cannon-Fenske Routine viscometer is a rugged and inexpensive viscometer that works well if the liquid to be measured is transparent or translucent.
  • In general, if the meniscus (the curvature at the top of the liquid column) can be readily observed through a column of liquid 3-mm in diameter,the Cannon-Fenske Routine viscometer can be used
  • The Cannon-Fenske Routine Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104.
  • Minimum bath depth is 203 mm (8 in).
  • Calibrated viscometers include a certificate of calibration and instruction sheet.
  • Holders are sold separately.
  • Sample volume : 7 ml
  • Precision : ±0.2%.
  • Brand : Cannon, USA

Model
Size
Constant
Viscosity Range
CANNON 9721-B50
25
0.002 cSt/sec
0.5 to 2.0 cSt
CANNON 9721-B53
50
0.004 cSt/sec
0.8 to 4.0 cSt
CANNON 9721-B56
75
0.008 cSt/sec
1.6 to 8.0 cSt
CANNON 9721-B59
100
0.015 cSt/sec
3.0 to 15 cSt
CANNON 9721-B62
150
0.035 cSt/sec
7.0 to 35 cSt
CANNON 9721-B65
200
0.1 cSt/sec
20 to 100 cSt
CANNON 9721-B68
300
0.25 cSt/sec
50 to 250 cSt
CANNON 9721-B71
350
0.5 cSt/sec
100 to 500 cSt
CANNON 9721-B74
400
1.2 cSt/sec
240 to 1200 cSt
CANNON 9721-B77
450
2.5 cSt/sec
500 to 2500 cSt
CANNON 9721-B80
500
8.0 cSt/sec
1600 to 8000 cSt
CANNON 9721-B83
600
20 cSt/sec
4000 to 20000 cSt
CANNON 9721-B86
650
45 cSt/sec
9000 to 45000 cSt
CANNON 9721-B89
700
100 cSt/sec
20000 to 100000 cSt

 

 

 

GLASS CAPILLARY VISCOMETER (UBBELOHDE)
Brand : Cannon

  • Cannon-Ubbelohde Viscometers.
  • The Ubbelohde viscometer is use to measure kinematic viscosities in transparent Newtonian liquids such as jet and hydraulic lubricants.
  • Unlike the Cannon-Fenske Routine viscometer, suspended level viscometers possess the same viscometer constant at all temperatures. This property is advantageous when measurements are to be made at a number of different temperatures.
  • Especially well suited for temperatures above 93°C (200°F) or below -18°C (0°F).
  • No kinetic energy corrections are required over a range of 0.5-100,000 cSt.
  • Each viscometer is calibrated in accordance with ASTM D445 and ISO 3104
  • Provided with certificate of calibration and instruction sheet.
  • Holder is not supplied.
  • Minimum bath depth is 254 mm (10 in) but it must be submerged to 220 mm (8.5 in).
  • Sample volume : 11 ml
  • Precision : ± 0.2%
  • Brand : Cannon, USA

Model
Size
Constant
Viscosity Range
CANNON 9721-K50
25
0.002 cSt/sec
0.5 to 2.0 cSt
CANNON 9721-K53
50
0.004 cSt/sec
0.8 to 4.0 cSt
CANNON 9721-K56
75
0.008 cSt/sec
1.6 to 8.0 cSt
CANNON 9721-K59
100
0.015 cSt/sec
3.0 to 15 cSt
CANNON 9721-K62
150
0.035 cSt/sec
7.0 to 35 cSt
CANNON 9721-K65
200
0.1 cSt/sec
20 to 100 cSt
CANNON 9721-K68
300
0.25 cSt/sec
50 to 250 cSt
CANNON 9721-K71
350
0.5 cSt/sec
100 to 500 cSt
CANNON 9721-K74
400
1.2 cSt/sec
240 to 1200 cSt
CANNON 9721-K77
450
2.5 cSt/sec
500 to 2500 cSt
CANNON 9721-K80
500
8.0 cSt/sec
1600 to 8000 cSt
CANNON 9721-K83
600
20 cSt/sec
4000 to 20000 cSt
CANNON 9721-K86
650
45 cSt/sec
9000 to 45000 cSt
CANNON 9721-K89
700
100 cSt/sec
20000 to 100000 cSt

 

 

 

GLASS CAPILLARY VISCOMETER (FENSKE OPAQUE)
Brand : Cannon

  • Special reverse flow viscometers have been designed for testing opaque liquids. Reverse flow viscometers wet the
    timing section of the viscometer capillary only during the actual measurement. The Cannon-Fenske Opaque viscometers are all reverse flow types.
  • Reverse flow viscometers must be cleaned, dried, and refilled before a repeat measurement can be made. By contrast, other viscometer types commonly used to measure transparent liquids allow the same sample to be repeatedly drawn up into the capillary, permitting multiple measurements for verification.
  • The Cannon-Fenske Opaque Viscometer measures kinematic viscosity of transparent and opaque Newtonian liquids according to ASTM D445, ISO 3104 and ASTM D2170.
  • Minimum bath depth is 230 mm (9 in).
  • Special constant viscometers are available at additional cost.
  • Calibrated viscometers include a certificate of calibration and instruction sheet.
  • Holders are sold separately.
  • Sample volume : 12 ml
  • Precision : ±0.3%.
  • Brand : Cannon, USA

Model
Size
Constant
Viscosity Range
CANNON 9721-F50
25
0.002 cSt/sec
0.4 to 2.0 cSt
CANNON 9721-F53
50
0.004 cSt/sec
0.8 to 4.0 cSt
CANNON 9721-F56
75
0.008 cSt/sec
1.6 to 8.0 cSt
CANNON 9721-F59
100
0.015 cSt/sec
3.0 to 15 cSt
CANNON 9721-F62
150
0.035 cSt/sec
7.0 to 35 cSt
CANNON 9721-F65
200
0.1 cSt/sec
20 to 100 cSt
CANNON 9721-F68
300
0.25 cSt/sec
50 to 250 cSt
CANNON 9721-F71
350
0.5 cSt/sec
100 to 500 cSt
CANNON 9721-F74
400
1.2 cSt/sec
240 to 1200 cSt
CANNON 9721-F77
450
2.5 cSt/sec
500 to 2500 cSt
CANNON 9721-F80
500
8.0 cSt/sec
1600 to 8000 cSt
CANNON 9721-F83
600
20 cSt/sec
4000 to 20000 cSt
CANNON 9721-F86
650
45 cSt/sec
9000 to 45000 cSt
CANNON 9721-F89
700
100 cSt/sec
20000 to 100000 cSt

 

 

 

UNI-CYLINDER ROTATIONAL VISCOTESTER
Brand / Model : Rion / VT-06

  • The VT-06 is designed for quality control applications in the manufacturing process of industrial products such as petrochemicals, paint, and adhesives, as well as foodstuffs.
  • Viscosity measurements covering a wide range are possible, such as gear oil used in construction machinery.
  • Measurement is performed by simply submerging a rotor in the fluid. The resistance to rotor movement caused by the viscosity (torque) is measured to obtain direct readings.
  • Compact and light weight make the unit easily portable and allow operation with one hand
  • Can be powered by alkaline batteries, nickel-hydride rechargeable batteries, or AC adapter
  • Direct indication of viscosity in decipascal-seconds (SI units)
  • Dedicated stand (VA-04) for measurement available as option
  • Range Rotor 1 : 3 to 150 dPa.s
  • Range Rotor 2 : 100 to 4000 dPa.s
  • Range Rotor 3 : 0.3 to 13 dPa.s
  • Sample Fluid Capacity (Rotor 1 & 2 ) : 300 ml
  • Sample Fluid Capacity (Rotor 3 ) : 150 ml
  • Brand : Rion, Japan

 

 

© 2008 A.R. ALATAN SAINS (K) SDN. BHD.